Parameters |
Factory Lead Time |
1 Week |
Mount |
PCB |
Mounting Type |
Through Hole |
Package / Case |
Module, Single Pass Through |
Housing Material |
PBT |
Operating Temperature |
-40°C~85°C |
Packaging |
Bulk |
Published |
1998 |
Series |
CSN |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Number of Terminations |
3 |
Voltage - Supply |
±12V~15V |
Terminal Position |
UNSPECIFIED |
Peak Reflow Temperature (Cel) |
NOT SPECIFIED |
Number of Functions |
1 |
Current Rating |
90A |
Frequency |
150kHz |
Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
Output |
Ratiometric, Current |
JESD-30 Code |
R-XXSS-T3 |
Operating Supply Voltage |
15V |
Number of Channels |
1 |
Analog IC - Other Type |
ANALOG CIRCUIT |
Polarization |
Bidirectional |
Nominal Supply Current |
10mA |
Output Current |
50mA |
Max Supply Current |
10mA |
Accuracy |
±0.5% |
Response Time |
0.5μs |
Coil Resistance |
30Ohm |
Sensor Type |
Hall Effect, Closed Loop |
Linearity |
0.1 % |
Max Supply Voltage (DC) |
15V |
Min Supply Voltage (DC) |
12V |
For Measuring |
AC/DC |
Width |
36.5mm |
REACH SVHC |
No SVHC |
RoHS Status |
RoHS Compliant |
CSNP661-002 Overview
For safety reasons, the current sensors are packaged in Module, Single Pass Through packages. As a safety measure, the current sensors are packaged inside the Bulk to prevent damage to the devices. It is recommended that current sensors do not supply a current greater than 10mA. Currently, the sensors have 3 terminations. A current sensor is designed for a current of 90A. When operating, the current sensors could deliver a voltage of 15V. Accordingly, the current provided by current sensors should have a nominal value of 10mA. The current output from current sensors should be 50mA. It is important that the voltage supplied by these sensors is not lower than 12V in a DC circuit. Nevertheless, the DC circuit voltage should not exceed 15V when the current sensors are being used.
CSNP661-002 Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -40°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Closed Loop
Supply Voltage: ±12V~15V
Frequency: 150kHz
Module, Single Pass Through Package
CSNP661-002 Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSNP661-002 Current Sensors applications.
- Continuity
- Power supply management
- Closed-L oop DC- and AC-Current Sensor Modules
- AC variabel speed drives and servo motor drives
- Battery supplied applications
- Power factor correction
- Battery chargers and systems
- Uninterruptible Power Supplies(UPS)
- Overcurrent Detection
- Leakage Current Sensors