Parameters |
Factory Lead Time |
1 Week |
Mount |
Surface Mount |
Mounting Type |
Surface Mount |
Package / Case |
10-TFSOP, 10-MSOP (0.118, 3.00mm Width) Exposed Pad |
Number of Pins |
10 |
Operating Temperature |
-40°C~125°C |
Packaging |
Tube |
Published |
2006 |
Part Status |
Obsolete |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Number of Terminations |
10 |
ECCN Code |
EAR99 |
Subcategory |
Operational Amplifier |
Technology |
BICMOS |
Terminal Position |
DUAL |
Terminal Form |
GULL WING |
Peak Reflow Temperature (Cel) |
NOT SPECIFIED |
Number of Functions |
1 |
Supply Voltage |
5V |
Terminal Pitch |
0.5mm |
Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
Number of Circuits |
1 |
Operating Supply Current |
3.7mA |
Slew Rate |
180V/μs |
Amplifier Type |
Differential |
Common Mode Rejection Ratio |
130 dB |
Current - Input Bias |
30nA |
Voltage - Supply, Single/Dual (±) |
2.7V~13.2V |
Output Current per Channel |
60mA |
Input Offset Voltage (Vos) |
200μV |
Bandwidth |
180MHz |
Gain Bandwidth Product |
400MHz |
Neg Supply Voltage-Nom (Vsup) |
-5V |
Average Bias Current-Max (IIB) |
0.75μA |
Voltage - Input Offset |
200μV |
Length |
3mm |
RoHS Status |
ROHS3 Compliant |
MAX44205AUB+ Overview
There is a 10-TFSOP, 10-MSOP (0.118, 3.00mm Width) Exposed Pad case in which the instrumentation amplifier is packaged. This is a Differential type op amp. A Tube case is used to deliver the buffer op amp. It is estimated that there will be at least 10 terminations this year. Please take in mind that op amp should be run at 5V. It should be noted that this type of buffer amplifier is exactly what is known as a Operational Amplifier device. 10 pins are included on the operational amplifiers. With regard to input offset voltage, instrumentation amplifier is rated at 200μV. This electronic part is best mounted with type Surface Mount. In terms of operating temperature, this instrumentation amplifier is well suited to a temperature range of -40°C~125°C. Using an 3.7mA supply current, this operational amplifier ics can be operated. A instrumentation amplifier like this has 1 circuits.
MAX44205AUB+ Features
supply voltage of 5V
MAX44205AUB+ Applications
There are a lot of Maxim Integrated MAX44205AUB+ Instrumentational OP Amps applications.
- Comparator
- Subtraction operation circuits
- Proportional operation circuits
- Medical instruments
- Differentiator circuits
- Medical imaging
- Wireless base stations
- Test equipment
- Automation control systems
- High speed sample