Parameters |
Factory Lead Time |
1 Week |
Mount |
Through Hole |
Mounting Type |
Through Hole |
Package / Case |
TO-46 |
Number of Pins |
3 |
Operating Temperature |
-55°C~125°C |
Packaging |
Bulk |
Published |
1997 |
Part Status |
Obsolete |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Max Operating Temperature |
125°C |
Min Operating Temperature |
-55°C |
Max Power Dissipation |
150mW |
Number of Elements |
1 |
Polarity |
NPN |
Power Dissipation |
150mW |
Viewing Angle |
90° |
Response Time |
75μs |
Rise Time |
75μs |
Fall Time (Typ) |
75 μs |
Collector Emitter Voltage (VCEO) |
15V |
Collector Emitter Breakdown Voltage |
15V |
Wavelength |
880nm |
Collector Emitter Saturation Voltage |
1.1V |
Dark Current |
250nA |
Current - Dark (Typ) |
250nA |
Diameter |
5.56mm |
Height |
3.89mm |
Length |
12.7mm |
RoHS Status |
RoHS Compliant |
SD3410-001 Overview
In order to protect these photodiodes from damage, they are packaged in the Bulk. It is necessary to enclose the photodiodes in TO-46 packages for safety purposes. A photodiode is equipped with 3 pins. Within the circuit, photodiodes are capable of releasing 150mW heat. When photodiodes operate, they should not be subjected to temperatures higher than 125°C. There should, however, be a minimum operating temperature of -55°C for the photodiodes. For a circuit, the maximum heat released by the photodiodes should be 150mW. Despite the absence of light, photodiodes make 250nA current.
SD3410-001 Features
Moisture Sensitivity Level (MSL): 1 (Unlimited)
Operating Temperature: -55°C~125°C
Packaging: Bulk
Mount: Through Hole
Response Time: 75μs
Viewing Angle: 90°
SD3410-001 Applications
There are a lot of Honeywell Sensing and Productivity Solutions SD3410-001 Photodiodes applications.
- Optical Switches
- Low Capacitance
- High speed photo detectors
- Low Cost Light Monitoring
- Measurement Levelling
- Industrial Automation
- Diode Laser Monitoring
- Solar Cells
- Machine Controls
- Pulse Oximetry