Power Transformers Dual Secondary, Open 120VA, 44V CT @2.73A


  • Manufacturer: Hammond Manufacturing
  • Nocochips NO: 348-182M22
  • Package: -
  • Datasheet: PDF
  • Stock: 938
  • Description: Power Transformers Dual Secondary, Open 120VA, 44V CT @2.73A(Kg)

Details

Tags

Parameters
Factory Lead Time 1 Week
Mount Chassis Mount, Panel
Mounting Type Chassis Mount
Weight 2.9lbs 1.3kg
Published 2008
Series 182
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Termination Wire Leads
ECCN Code EAR99
Type Toroidal
Power Rating 120W
Max Power Dissipation 120W
Termination Style Wire Leads
Approval Agency CE, CSA, UL
Voltage - Isolation 4000Vrms
Output Voltage 22V
Max Output Current 2.73A
Current - Output (Max) Parallel 5.46A Series 2.73A
Output Current 5.46A
Power - Max 120VA
Voltage - Primary 117V 234V
Primary Winding(s) Dual
Center Tap No
Voltage - Secondary (Full Load) Parallel 22V Series 44V
Secondary Current 5.46A
Diameter 101mm
Height 42.7mm
Height Seated (Max) 42.67mm
REACH SVHC No SVHC
RoHS Status ROHS3 Compliant