RoHS Status ROHS3 Compliant
Factory Lead Time 1 Week
Mount Panel, Screw
Mounting Type Panel Mount
Package / Case Module, Single Pass Through
Operating Temperature -40°C~85°C
Packaging Bulk
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Max Operating Temperature 85°C
Min Operating Temperature -40°C
Voltage - Supply 12V~15V
Current Rating 200A
Frequency 100kHz
Output Ratiometric, Voltage
Current - Supply (Max) 20mA
Operating Supply Voltage 15V
Polarity Bidirectional
Number of Channels 1
Polarization Bidirectional
Max Supply Current 20mA
Accuracy ±0.8%
Response Time 1μs
Sensor Type Hall Effect, Closed Loop
Linearity ±0.1%
Sensing Method Hall Effect
Max Supply Voltage (DC) 15V
Min Supply Voltage (DC) 12V
For Measuring AC/DC
Current - Sensing 200A
Height 56.3mm
Length 66mm
Width 56.5mm
REACH SVHC No SVHC

20310200102 Overview


Module, Single Pass Through packages are used for the safety protection of current sensors. The current sensors are enclosed in the Bulk to prevent them from being damaged. These current sensors should be able to deliver a maximum current of 20mA. It is recommended that current sensors do not supply a current greater than 20mA. To ensure proper operation of these current sensors, the operating temperature cannot be below -40°C. It is recommended that the maximum operating temperature of the current sensors is set to 85°C. Current sensors have been designed to measure current at 200A. It is possible for the current sensors to supply 15V voltage when they are operating. In a DC circuit, these sensors must provide voltages greater than 12V. In the DC circuit, the voltage supplied by the current sensors should not exceed 15V.

20310200102 Features


Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -40°C~85°C
1 Channels
Mounting Type: Panel Mount
Sensor Type: Hall Effect, Closed Loop
Supply Voltage: 12V~15V
Frequency: 100kHz
Sensing Current: 200A
Module, Single Pass Through Package

20310200102 Applications


There are a lot of HARTING 20310200102 Current Sensors applications.

  • Battery chargers and systems
  • Switched Mode Power Supplies (SMPS)
  • OEM Current Sensing
  • Inverter and H-bridge current measurements
  • Home Automation
  • Industrial Monitoring and Control Systems
  • Monitor Motor Operation
  • Proving Switch
  • Electrical drives
  • Motor and load control