Parameters |
Terminal Form |
THROUGH-HOLE |
Peak Reflow Temperature (Cel) |
260 |
Number of Functions |
1 |
Supply Voltage |
5V |
Terminal Pitch |
2.54mm |
Time@Peak Reflow Temperature-Max (s) |
40 |
Base Part Number |
ACPL-7900 |
Output Type |
Analog, Digital |
Power Supplies |
3.3/55V |
Number of Circuits |
1 |
Operating Supply Current |
18.5mA |
Amplifier Type |
Isolation |
Current - Input Bias |
100nA |
Voltage - Supply, Single/Dual (±) |
3V~5V |
Output Current per Channel |
11mA |
Input Offset Voltage (Vos) |
600μV |
Bandwidth |
200 kHz |
Supply Voltage Limit-Max |
5.5V |
Voltage - Input Offset |
600μV |
-3db Bandwidth |
200MHz |
Isolation Voltage |
5kV |
Voltage Gain-Min |
7.95 |
Height Seated (Max) |
4.7mm |
Radiation Hardening |
No |
RoHS Status |
ROHS3 Compliant |
Factory Lead Time |
1 Week |
Mount |
Surface Mount |
Mounting Type |
Surface Mount |
Package / Case |
8-SMD, Gull Wing |
Number of Pins |
8 |
Operating Temperature |
-40°C~105°C |
Packaging |
Tape & Reel (TR) |
Published |
2010 |
JESD-609 Code |
e3 |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Number of Terminations |
8 |
ECCN Code |
EAR99 |
Terminal Finish |
Tin (Sn) |
Terminal Position |
DUAL |
ACPL-7900-500E Overview
Packaged in a 8-SMD, Gull Wing case, the buffer op amp is ready to use. Op amps are Isolation types of amplifier on the chip. As far as the packaging is concerned, buffer op amp is delivered in a Tape & Reel (TR) case. In recent months, the number of terminations has approached 8. As a reminder, this buffer op amp should be powered by 5V battery and that the battery should be inserted in the amplifier. 8 pins are located on the operational amplifiers. Op amp rates 600μV as input offset voltage. Surface Mount is the recommended mounting type of operational amplifiers. With regard to operating temperature, this op amp functions well at -40°C~105°C. The buffer amplifier is capable of operating from a supply current of 18.5mA . This op amp ic has 1 circuits. Buffer amplifier produces Analog, Digital signals, which is one of its many benefits. This op amp ic can conduct a minimum voltage gain of 7.95.
ACPL-7900-500E Features
supply voltage of 5V
Output Type: Analog, Digital
ACPL-7900-500E Applications
There are a lot of Broadcom Limited ACPL-7900-500E Instrumentational OP Amps applications.
- Non-polarized electrodes
- Weighing systems
- High-frequency data acquisition systems
- Test equipment
- Ultrasound transducers
- Video conversion and routing
- Signal transformation
- Polarized electrodes
- Car stereo
- Oscilloscopes