banner_page

ACS720KLATR-15AB-T

ACS720KLATR-15AB-T datasheet pdf and Current Sensors product details from Allegro MicroSystems stock available at Noco


  • Manufacturer: Allegro MicroSystems
  • Nocochips NO: 26-ACS720KLATR-15AB-T
  • Package: 16-SOIC (0.295, 7.50mm Width)
  • Datasheet: PDF
  • Stock: 770
  • Description: ACS720KLATR-15AB-T datasheet pdf and Current Sensors product details from Allegro MicroSystems stock available at Noco(Kg)

Details

Tags

Parameters
Factory Lead Time 1 Week
Mounting Type Surface Mount
Package / Case 16-SOIC (0.295, 7.50mm Width)
Surface Mount YES
Operating Temperature -40°C~125°C
Packaging Tape & Reel (TR)
Published 2017
Series ACS720
JESD-609 Code e3
Part Status Active
Moisture Sensitivity Level (MSL) 3 (168 Hours)
Number of Terminations 16
Terminal Finish Matte Tin (Sn)
Voltage - Supply 4.5V~5.5V
Terminal Position DUAL
Terminal Form GULL WING
Peak Reflow Temperature (Cel) NOT SPECIFIED
Number of Functions 1
Supply Voltage 5V
Time@Peak Reflow Temperature-Max (s) NOT SPECIFIED
Output Ratiometric, Current
Current - Supply (Max) 16mA
Supply Voltage-Max (Vsup) 5.5V
Supply Voltage-Min (Vsup) 4.5V
Number of Channels 1
Analog IC - Other Type ANALOG CIRCUIT
Polarization Bidirectional
Accuracy ±1.6%
Response Time 4μs (Typ)
Bandwidth 120 kHz
Sensor Type Hall Effect, Open Loop
Linearity ±0.75%
Sensitivity 90mV/A
For Measuring AC/DC
Current - Sensing 15A
Height Seated (Max) 2.65mm
RoHS Status ROHS3 Compliant

ACS720KLATR-15AB-T Overview


Safety precautions are taken by putting the current sensors in 16-SOIC (0.295, 7.50mm Width) packages. A protective Tape & Reel (TR) is placed over these current sensors in order to prevent damage to the devices. Ideally, these current sensors should supply a maximum current of 16mA. There is a termination of 16 on the current sensors. During operation, these current sensors are capable of supplying a voltage of 5V. Set current sensors' minimum voltage to 4.5V. Current sensors should, however, not exceed 5.5V in voltage.

ACS720KLATR-15AB-T Features


Moisture Sensitivity Level: 3 (168 Hours)
Operating Temperature: -40°C~125°C
1 Channels
Mounting Type: Surface Mount
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 4.5V~5.5V
Sensing Current: 15A
16-SOIC (0.295, 7.50mm Width) Package

ACS720KLATR-15AB-T Applications


There are a lot of Allegro MicroSystems ACS720KLATR-15AB-T Current Sensors applications.

  • Static converters for for DC motor drives
  • Continuity
  • Home Automation
  • Motor and load control
  • General purpose inverters
  • Proving Switch
  • OEM Current Sensing
  • DC and AC power monitoring
  • Battery chargers and systems
  • Frequency, Voltage, and Solar Inverters

Write a review

Note: HTML is not translated!
    Bad           Good