Parameters | |
---|---|
Configuration | Single |
Case Connection | ISOLATED |
RMS Current (Irms) | 25A |
Hold Current | 80mA |
Trigger Device Type | TRIAC |
Voltage - Off State | 400V |
Voltage - Gate Trigger (Vgt) (Max) | 1.3V |
Current - Non Rep. Surge 50, 60Hz (Itsm) | 250A 260A |
Current - Gate Trigger (Igt) (Max) | 50mA |
Current - On State (It (RMS)) (Max) | 25A |
Repetitive Peak Off-state Voltage | 400V |
Non-Repetitive Pk On-state Cur | 260 A |
Critical Rate of Rise of Off-State Voltage-Min | 250V/us |
Triac Type | Standard |
Desc. of Quick-Connects | G-MT1-MT2 |
Critical Rate of Rise of Commutation Voltage-Min | 10V/us |
Repetitive Peak Off-state Leakage Current-Max | 10μA |
RoHS Status | ROHS3 Compliant |
Mount | Chassis Mount, Through Hole |
Mounting Type | Chassis Mount |
Package / Case | RD91-3 (Insulated) |
Number of Pins | 91 |
Operating Temperature | -40°C~125°C TJ |
Packaging | Bulk |
Part Status | Obsolete |
Moisture Sensitivity Level (MSL) | 3 (168 Hours) |
Number of Terminations | 3 |
HTS Code | 8541.30.00.80 |
Subcategory | TRIACs |
Terminal Position | UPPER |
Terminal Form | SOLDER LUG |
Reach Compliance Code | unknown |
Base Part Number | BTA25 |
JESD-30 Code | O-PUFM-D3 |
Qualification Status | Not Qualified |
Number of Elements | 1 |