Parameters |
Factory Lead Time |
1 Week |
Mount |
Screw, Through Hole |
Mounting Type |
Through Hole |
Package / Case |
Module |
Operating Temperature |
-25°C~85°C |
Packaging |
Bulk |
Published |
1998 |
Series |
CSDA |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Max Operating Temperature |
85°C |
Min Operating Temperature |
-25°C |
Voltage - Supply |
6V~16V |
Current Rating |
12mA |
Output |
NPN |
Current - Supply (Max) |
12mA |
Output Voltage |
400mV |
Polarity |
Bidirectional |
Number of Channels |
1 |
Max Supply Voltage |
16V |
Min Supply Voltage |
6V |
Polarization |
Bidirectional |
Nominal Supply Current |
6.5A |
Max Supply Current |
12mA |
Accuracy |
±0.5% |
Max Output Voltage |
400mV |
Response Time |
100μs |
Sensor Type |
Current Switch |
Max Supply Voltage (DC) |
16V |
Min Supply Voltage (DC) |
6V |
For Measuring |
AC/DC |
Current - Sensing |
7.5A |
Length |
19mm |
REACH SVHC |
No SVHC |
RoHS Status |
RoHS Compliant |
CSDA1AC Overview
As a safety precaution, current sensors are placed in Module packages. In order to protect the devices from damage, these current sensors are packaged in the Bulk. These current sensors should supply 12mA current at their maximum. Current sensors should not supply more current than 12mA. It is important to make sure these current sensors work at temperatures higher than -25°C. It is recommended, however, to set the maximum operating temperature for the current sensors to 85°C. In the current sensor design, 12mA is the current for which the sensors are designed. As a rule of thumb, current sensors are supposed to supply a current of 6.5A. Current sensors should generate a voltage output of 400mV. The voltage supplied by these sensors should not be less than 6V in a DC circuit. It is however important that the voltage supplied by the current sensors in the DC circuit not exceed 16V.
CSDA1AC Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -25°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Current Switch
Supply Voltage: 6V~16V
Sensing Current: 7.5A
Module Package
CSDA1AC Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSDA1AC Current Sensors applications.
- Frequency, Voltage, and Solar Inverters
- Inverter and H-bridge current measurements
- Continuity
- Power Supplies for welding applications
- Overcurrent protection
- Uninterruptible Power Supplies(UPS)
- Monitor Motor Operation
- DC motor drives
- Switched Mode Power Supplies (SMPS)
- Power supply management