Parameters |
Factory Lead Time |
1 Week |
Mount |
PCB |
Mounting Type |
Through Hole |
Package / Case |
Module, Single Pass Through |
Number of Pins |
3 |
Housing Material |
PBT |
Operating Temperature |
-25°C~85°C |
Packaging |
Bulk |
Published |
1998 |
Series |
CSLA |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Termination |
Connector |
Max Operating Temperature |
85°C |
Min Operating Temperature |
-25°C |
Voltage - Supply |
8V~16V |
Current Rating |
19mA |
Output |
Ratiometric, Voltage |
Current - Supply (Max) |
19mA |
Output Type |
Voltage |
Polarity |
Bidirectional |
Number of Channels |
1 |
Max Supply Voltage |
16V |
Min Supply Voltage |
8V |
Polarization |
Bidirectional |
Nominal Supply Current |
19mA |
Max Supply Current |
19mA |
Max Voltage Rating (DC) |
16V |
Response Time |
3μs |
Wire/Cable Diameter |
10.9 mm |
Sensor Type |
Hall Effect, Open Loop |
Sensing Method |
Inductive |
Sensitivity |
49.6mV/N |
Max Supply Voltage (DC) |
16V |
Min Supply Voltage (DC) |
8V |
For Measuring |
AC/DC |
Current - Sensing |
57A |
Height |
35.56mm |
Length |
34.3mm |
Width |
10.414mm |
REACH SVHC |
Unknown |
RoHS Status |
RoHS Compliant |
CSLA1CD Overview
As a safety precaution, the current sensors are packaged in Module, Single Pass Through packages. The devices are protected from damage by the Bulk package. The maximum current supplied by these current sensors should be 19mA. There should be no current greater than 19mA coming from current sensors. Ensure that the operating temperature of the current sensor is not lower than -25°C. The current sensors should remain at 85°C for the maximum operating temperature. Current sensors have been designed to measure current at 19mA. This current sensor consists of 3 pins. As a rule of thumb, current sensors should supply 19mA current. The voltage supplied by these sensors cannot fall below 8V in a DC circuit. In the DC circuit, the voltage provided by the current sensors should not exceed 16V.
CSLA1CD Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -25°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 8V~16V
Sensing Current: 57A
Module, Single Pass Through Package
CSLA1CD Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA1CD Current Sensors applications.
- Static converters for for DC motor drives
- DC and AC power monitoring
- Battery supplied applications
- Power factor correction
- Motor and load control
- Inverter and H-bridge current measurements
- Switched Mode Power Supplies(SMPS)
- Uninterruptible Power Supplies(UPS)
- Battery chargers and systems
- Closed-L oop DC- and AC-Current Sensor Modules