Parameters |
Factory Lead Time |
1 Week |
Mount |
PCB |
Mounting Type |
Through Hole |
Package / Case |
Module, Single Pass Through |
Number of Pins |
3 |
Housing Material |
PBT |
Operating Temperature |
-25°C~85°C |
Packaging |
Bulk |
Published |
1998 |
Series |
CSLA |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Max Operating Temperature |
85°C |
Min Operating Temperature |
-25°C |
Voltage - Supply |
8V~16V |
Current Rating |
100A |
Output |
Ratiometric, Voltage |
Current - Supply (Max) |
19mA |
Output Type |
Voltage |
Polarity |
Bidirectional |
Number of Channels |
1 |
Max Supply Voltage |
16V |
Min Supply Voltage |
8V |
Polarization |
Bidirectional |
Nominal Supply Current |
19mA |
Max Supply Current |
19mA |
Response Time |
3μs |
Wire/Cable Diameter |
10.9 mm |
Sensor Type |
Hall Effect, Open Loop |
Sensitivity |
29.7mV/N |
Max Supply Voltage (DC) |
16V |
Min Supply Voltage (DC) |
8V |
For Measuring |
AC/DC |
Current - Sensing |
100A |
Length |
34.3mm |
REACH SVHC |
Unknown |
RoHS Status |
RoHS Compliant |
CSLA1CF Overview
Safety reasons require that the current sensors be placed in Module, Single Pass Through packages. To protect the current sensors against damage, they have been packaged in the Bulk. They should be capable of supplying a maximum current of 19mA. A current sensor should provide a current no greater than 19mA. These current sensors must operate at a temperature greater than -25°C in order to be effective. However, the maximum operating temperature for the current sensors should be set to 85°C. In the current sensor design, 100A is the current for which the sensors are designed. The current sensor has 3 pins. Nominally, the current supplied by current sensors should be 19mA. In a DC circuit, the voltage supplied by these sensors should not be lower than 8V. In the DC circuit, the current sensors should not provide a voltage greater than 16V.
CSLA1CF Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -25°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 8V~16V
Sensing Current: 100A
Module, Single Pass Through Package
CSLA1CF Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA1CF Current Sensors applications.
- Overcurrent Detection
- AC variable speed drives
- Industrial Monitoring and Control Systems
- DC motor drives
- Uninterruptible Power Supplies(UPS)
- Monitor Motor Operation
- Static converters for for DC motor drives
- OEM Current Sensing
- Battery supplied applications
- Power Supplies for welding applications