banner_page

CSLA1CH

CSLA1CH datasheet pdf and Current Sensors product details from Honeywell Sensing and Productivity Solutions stock available at Noco


  • Manufacturer: Honeywell Sensing and Productivity Solutions
  • Nocochips NO: 384-CSLA1CH
  • Package: Module, Single Pass Through
  • Datasheet: PDF
  • Stock: 390
  • Description: CSLA1CH datasheet pdf and Current Sensors product details from Honeywell Sensing and Productivity Solutions stock available at Noco(Kg)

Details

Tags

Parameters
Min Operating Temperature -25°C
Voltage - Supply 8V~16V
Current Rating 19mA
Output Ratiometric, Voltage
Current - Supply (Max) 19mA
Operating Supply Voltage 91.215kV
Polarity Bidirectional
Number of Channels 1
Polarization Bidirectional
Max Supply Current 19mA
Response Time 3μs
Sensor Type Hall Effect, Open Loop
Sensitivity 19.6mV/N
Max Supply Voltage (DC) 16V
Min Supply Voltage (DC) 8V
For Measuring AC/DC
Current - Sensing 150A
Height 35.6mm
Length 34.3mm
Width 10.4mm
RoHS Status RoHS Compliant
Factory Lead Time 1 Week
Mount Through Hole
Mounting Type Through Hole
Package / Case Module, Single Pass Through
Number of Pins 3
Operating Temperature -25°C~85°C
Packaging Bulk
Published 1998
Series CSLA
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Max Operating Temperature 85°C

CSLA1CH Overview


A Module, Single Pass Through package is used for the protection of the current sensors. The current sensors are packaged in the Bulk in order to prevent damage to the devices. There should be 19mA as the maximum current supplied by these current sensors. No more than 19mA current should be supplied by current sensors. This current sensor must function at temperatures greater than -25°C at all times. Nevertheless, the current sensors should be set to 85°C as the maximum operating temperature. For the current sensors, the current is 19mA. In this current sensor, there are no pins. When the current sensors are operating, they could supply 91.215kV. DC circuits must have a voltage that does not fall below 8V. In the DC circuit, the voltage supplied by the current sensors should not exceed 16V.

CSLA1CH Features


Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -25°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 8V~16V
Sensing Current: 150A
Module, Single Pass Through Package

CSLA1CH Applications


There are a lot of Honeywell Sensing and Productivity Solutions CSLA1CH Current Sensors applications.

  • Frequency, Voltage, and Solar Inverters
  • Battery supplied applications
  • Power supplies for welding applications
  • Overcurrent Detection
  • Battery supplied applications
  • Uninterruptible Power Supplies(UPS)
  • Proving Switch
  • Uninterruptable Power Supllies (UPS)
  • Overcurrent protection
  • Electrical drives

Write a review

Note: HTML is not translated!
    Bad           Good