Parameters |
Polarity |
Bidirectional |
Number of Channels |
1 |
Max Supply Voltage |
16V |
Min Supply Voltage |
8V |
Polarization |
Bidirectional |
Nominal Supply Current |
19mA |
Max Supply Current |
19mA |
Accuracy |
2 % |
Response Time |
3μs |
Sensor Type |
Hall Effect, Open Loop |
Sensing Method |
Hall Effect |
Sensitivity |
5.6mV/N |
Max Supply Voltage (DC) |
16V |
Min Supply Voltage (DC) |
8V |
For Measuring |
AC/DC |
Current - Sensing |
625A |
REACH SVHC |
Unknown |
RoHS Status |
RoHS Compliant |
Factory Lead Time |
1 Week |
Mount |
PCB |
Mounting Type |
Through Hole |
Package / Case |
Module, Single Pass Through |
Housing Material |
PBT |
Operating Temperature |
-25°C~85°C |
Packaging |
Bulk |
Published |
1998 |
Series |
CSLA |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Max Operating Temperature |
85°C |
Min Operating Temperature |
-25°C |
Voltage - Supply |
8V~16V |
Current Rating |
625A |
Output |
Ratiometric, Voltage |
Current - Supply (Max) |
19mA |
Output Type |
Voltage |
CSLA1EL Overview
Safety measures are taken to protect the current sensors by putting them in Module, Single Pass Through packages. For protection, these current sensors are packaged in a Bulk. Ideally, these current sensors should supply a maximum current of 19mA. It is recommended that current sensors provide a current that is not greater than 19mA. It is important to make sure these current sensors work at temperatures higher than -25°C. For the current sensors, however, the maximum operating temperature should be set to 85°C. In this case, the current sensors were designed for 625A current. As a general rule, current sensors should supply an electrical current of 19mA. Sensors should supply voltages above 8V in DC circuits. In the DC circuit, the voltage supplied by the current sensors should however not exceed 16V.
CSLA1EL Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -25°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 8V~16V
Sensing Current: 625A
Module, Single Pass Through Package
CSLA1EL Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA1EL Current Sensors applications.
- Frequency, Voltage, and Solar Inverters
- Power Supplies for welding applications
- Static converters for for DC motor drives
- Home Automation
- Continuity
- Overcurrent Detection
- Closed-L oop DC- and AC-Current Sensor Modules
- Overcurrent protection
- Power supply management
- Monitor Motor Operation