Parameters |
Factory Lead Time |
1 Week |
Mount |
PCB |
Mounting Type |
Through Hole |
Package / Case |
Module, Single Pass Through |
Number of Pins |
3 |
Housing Material |
PBT |
Operating Temperature |
-25°C~85°C |
Packaging |
Bulk |
Published |
1998 |
Series |
CSLA |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Max Operating Temperature |
85°C |
Min Operating Temperature |
-25°C |
Voltage - Supply |
6V~12V |
Current Rating |
125A |
Output |
Ratiometric, Voltage |
Current - Supply (Max) |
20mA |
Output Type |
Voltage |
Polarity |
Bidirectional |
Number of Channels |
1 |
Max Supply Voltage |
12V |
Min Supply Voltage |
6V |
Polarization |
Bidirectional |
Nominal Supply Current |
20mA |
Max Supply Current |
20mA |
Response Time |
3μs |
Sensor Type |
Hall Effect, Open Loop |
Sensitivity |
19.6mV/N |
Max Supply Voltage (DC) |
12V |
Min Supply Voltage (DC) |
6V |
For Measuring |
AC/DC |
Current - Sensing |
125A |
Length |
34.3mm |
REACH SVHC |
No SVHC |
RoHS Status |
RoHS Compliant |
CSLA2CF Overview
For safety reasons, the current sensors are enclosed in Module, Single Pass Through packages. It is designed to protect the current sensors from damage by packaging them in the Bulk. There should be 20mA as the maximum current supplied by these current sensors. A current sensor should provide a current no greater than 20mA. It is important to make sure these current sensors work at temperatures higher than -25°C. As a result, the maximum operating temperature should be set to 85°C for the current sensors. For the current sensors, the current is 125A. In this current sensor, there are no pins. As a rule of thumb, current sensors are supposed to supply a current of 20mA. It is important that the voltage supplied by these sensors is not lower than 6V in a DC circuit. It is important, however, that the voltage supplied by the current sensors does not exceed 12V in the DC circuit.
CSLA2CF Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -25°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 6V~12V
Sensing Current: 125A
Module, Single Pass Through Package
CSLA2CF Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA2CF Current Sensors applications.
- Static converters for DC motor drives
- Continuity
- Uninterruptible Power Supplies(UPS)
- Switched Mode Power Supplies(SMPS)
- Battery supplied applications
- AC variabel speed drives and servo motor drives
- Static converters for for DC motor drives
- Power supply management
- Power factor correction
- AC variable speed drives