banner_page

CSLA2DG

CSLA2DG datasheet pdf and Current Sensors product details from Honeywell Sensing and Productivity Solutions stock available at Noco


  • Manufacturer: Honeywell Sensing and Productivity Solutions
  • Nocochips NO: 384-CSLA2DG
  • Package: Module, Single Pass Through
  • Datasheet: PDF
  • Stock: 292
  • Description: CSLA2DG datasheet pdf and Current Sensors product details from Honeywell Sensing and Productivity Solutions stock available at Noco(Kg)

Details

Tags

Parameters
Factory Lead Time 1 Week
Mount PCB, Through Hole
Mounting Type Through Hole
Package / Case Module, Single Pass Through
Number of Pins 3
Operating Temperature -25°C~85°C
Packaging Bulk
Published 1998
Series CSLA
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Max Operating Temperature 85°C
Min Operating Temperature -25°C
Voltage - Supply 6V~12V
Current Rating 150A
Output Ratiometric, Voltage
Current - Supply (Max) 20mA
Polarity Bidirectional
Number of Channels 1
Max Supply Voltage 12V
Min Supply Voltage 6V
Polarization Bidirectional
Nominal Supply Current 20mA
Max Supply Current 20mA
Response Time 3μs
Wire/Cable Diameter 15.7 mm
Sensor Type Hall Effect, Open Loop
Sensitivity 16.2mV/N
Max Supply Voltage (DC) 12V
Min Supply Voltage (DC) 6V
For Measuring AC/DC
Current - Sensing 150A
REACH SVHC Unknown
RoHS Status RoHS Compliant

CSLA2DG Overview


In order to ensure safety, the current sensors are packaged in Module, Single Pass Through packages. Current sensors are packaged in the Bulk for protection. It is recommended that these current sensors supply a maximum current of 20mA. It is important that current sensors do not supply more current than 20mA. To make these current sensors work, their operating temperature must not fall below -25°C. Current sensors should, however, be set to 85°C for their maximum operating temperature. Current sensors are designed to detect 150A current. Currently, this sensor has 3 pins. The nominal current supplied by current sensors should be 20mA. The sensors should provide voltages not less than 6V in DC circuits. It is important, however, that the voltage supplied by the current sensors does not exceed 12V in the DC circuit.

CSLA2DG Features


Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -25°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 6V~12V
Sensing Current: 150A
Module, Single Pass Through Package

CSLA2DG Applications


There are a lot of Honeywell Sensing and Productivity Solutions CSLA2DG Current Sensors applications.

  • DC motor drives
  • Closed-L oop DC- and AC-Current Sensor Modules
  • Home Automation
  • Power supplies for welding applications
  • Battery supplied applications
  • Inverter and H-bridge current measurements
  • Power Supplies for welding applications
  • OEM Current Sensing
  • Continuity
  • Monitor Motor Operation

Write a review