Parameters |
Factory Lead Time |
1 Week |
Mount |
Through Hole |
Mounting Type |
Through Hole |
Package / Case |
Module, Single Pass Through |
Number of Pins |
3 |
Operating Temperature |
-25°C~85°C |
Packaging |
Bulk |
Published |
1998 |
Series |
CSLA |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Max Operating Temperature |
85°C |
Min Operating Temperature |
-25°C |
Voltage - Supply |
6V~12V |
Current Rating |
20mA |
Output |
Ratiometric, Voltage |
Current - Supply (Max) |
20mA |
Operating Supply Voltage |
9V |
Polarity |
Bidirectional |
Number of Channels |
1 |
Max Supply Voltage |
12V |
Min Supply Voltage |
6V |
Polarization |
Bidirectional |
Output Current |
1mA |
Max Supply Current |
20mA |
Response Time |
3μs |
Sensor Type |
Hall Effect, Open Loop |
Sensitivity |
5.8mV/N |
Max Supply Voltage (DC) |
12V |
Min Supply Voltage (DC) |
6V |
For Measuring |
AC/DC |
Current - Sensing |
400A |
REACH SVHC |
Unknown |
RoHS Status |
RoHS Compliant |
CSLA2DK Overview
Current sensors are packaged in Module, Single Pass Through packages to ensure their safety. To protect the current sensors against damage, they have been packaged in the Bulk. Ideally, these current sensors should supply a maximum current of 20mA. The current supplied by current sensors should not be higher than 20mA. To ensure that these current sensors function properly, the operating temperature must not be lower than -25°C. Nevertheless, the maximum operating temperature for the current sensors should be set to 85°C. There is no current for which the current sensors have been designed. In this current sensor, there are no pins. During operation, the current sensors may supply a voltage of 9V. It is recommended that current sensors produce a 1mA current output. This sensors should supply a voltage not less than 6V in a DC circuit. As long as the voltage supplied by the current sensors is below 12V in the DC circuit, the sensor's output cannot be damaged.
CSLA2DK Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -25°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 6V~12V
Sensing Current: 400A
Module, Single Pass Through Package
CSLA2DK Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA2DK Current Sensors applications.
- Industrial Monitoring and Control Systems
- Continuity
- Mobile applications
- Overcurrent protection
- AC variable speed drives
- Uninterruptable Power Supllies (UPS)
- Static converters for DC motor drives
- Overcurrent Detection
- Battery supplied applications
- DC and AC power monitoring