Parameters |
Factory Lead Time |
1 Week |
Mount |
Through Hole |
Mounting Type |
Through Hole |
Package / Case |
Module, Single Pass Through |
Number of Pins |
3 |
Operating Temperature |
-25°C~85°C |
Packaging |
Bulk |
Published |
1998 |
Series |
CSLA |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Max Operating Temperature |
85°C |
Min Operating Temperature |
-25°C |
Voltage - Supply |
6V~12V |
Current Rating |
20mA |
Output |
Ratiometric, Voltage |
Current - Supply (Max) |
20mA |
Operating Supply Voltage |
9V |
Polarity |
Bidirectional |
Number of Channels |
1 |
Max Supply Voltage |
12V |
Min Supply Voltage |
6V |
Polarization |
Bidirectional |
Nominal Supply Current |
20mA |
Max Supply Current |
20mA |
Response Time |
3μs |
Sensor Type |
Hall Effect, Open Loop |
Sensitivity |
7.6mV/N |
Max Supply Voltage (DC) |
12V |
Min Supply Voltage (DC) |
6V |
For Measuring |
AC/DC |
Current - Sensing |
310A |
REACH SVHC |
Unknown |
RoHS Status |
RoHS Compliant |
CSLA2EJ Overview
As a safety precaution, current sensors are placed in Module, Single Pass Through packages. In order to protect the devices from damage, these current sensors are packaged in the Bulk. The maximum current supplied by these current sensors should be 20mA. There should be no current greater than 20mA coming from current sensors. To ensure proper operation of these current sensors, the operating temperature cannot be below -25°C. It is recommended, however, to set the maximum operating temperature for the current sensors to 85°C. It has been designed for 20mA current to be sensed by the current sensors. Current sensors have 3 pins. It is possible for the current sensors to supply 9V voltage when they are operating. The nominal current supplied by current sensors is 20mA. It is recommended that the voltage supplied by these sensors should not be lower than 6V ina DC circuit. Current sensors should not supply more voltage than 12V in DC circuits.
CSLA2EJ Features
Moisture Sensitivity Level: 1 (Unlimited)
Operating Temperature: -25°C~85°C
1 Channels
Mounting Type: Through Hole
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 6V~12V
Sensing Current: 310A
Module, Single Pass Through Package
CSLA2EJ Applications
There are a lot of Honeywell Sensing and Productivity Solutions CSLA2EJ Current Sensors applications.
- Power supplies for welding applications
- Power supply management
- Leakage Current Sensors
- AC variable speed drives
- DC motor drives
- AC variabel speed drives and servo motor drives
- DC and AC power monitoring
- Uninterruptible Power Supplies(UPS)
- Switched Mode Power Supplies(SMPS)
- Closed-L oop DC- and AC-Current Sensor Modules