Parameters | |
---|---|
Applications | Medical |
Power (Watts) | 100W 130W Forced Air |
Power Rating | 130W |
Technology | HYBRID |
Terminal Position | UNSPECIFIED |
Terminal Form | UNSPECIFIED |
Number of Functions | 1 |
Frequency | 63Hz |
JESD-30 Code | R-XXMA-X11 |
Number of Outputs | 3 |
Approval Agency | CE |
Efficiency | 90% |
Voltage - Isolation | 4000V |
Output Voltage | 5V |
Input Voltage-Nom | 115V |
Trim/Adjustable Output | YES |
Voltage - Input | 90V~264VAC |
Output Current | 10A |
Output Power | 130W |
Voltage - Output 2 | 15V |
Min Input Voltage | 90V |
Max Input Voltage | 264V |
Current - Output 1 | 10A |
Voltage - Output 3 | -15V |
Max Output Power | 130W |
Minimum Load Required | Yes |
Input Current | 2.6A |
Current - Output 2 | 2.5A |
Min Input Voltage (AC) | 90V |
Max Input Voltage (AC) | 264V |
Current - Output 3 | 800mA |
Height | 34.4mm |
REACH SVHC | Unknown |
RoHS Status | RoHS Compliant |
Factory Lead Time | 1 Week |
Mounting Type | Chassis Mount |
Surface Mount | NO |
Operating Temperature | 0°C~70°C With Derating |
Published | 2009 |
Series | JPS (130W) |
Size / Dimension | 5.00Lx3.00W x 1.18 H 127.0mmx76.2mmx30.0mm |
Feature | Adjustable Output, DC Input Capable, PFC, Remote Sense, Standby Output, Universal Input |
Part Status | Active |
Moisture Sensitivity Level (MSL) | Not Applicable |
Number of Terminations | 11 |
Type | Open Frame |