Parameters |
Lifecycle Status |
ACTIVE (Last Updated: 1 week ago) |
Mount |
Through Hole |
Package / Case |
CDIP |
Number of Pins |
14 |
Moisture Sensitivity Level (MSL) |
1 |
Number of Terminations |
14 |
ECCN Code |
EAR99 |
Max Operating Temperature |
125°C |
Min Operating Temperature |
-55°C |
Subcategory |
Comparator |
Packing Method |
TUBE |
Technology |
BIPOLAR |
Terminal Position |
DUAL |
Peak Reflow Temperature (Cel) |
NOT SPECIFIED |
Number of Functions |
2 |
Supply Voltage |
15V |
Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
Pin Count |
14 |
Qualification Status |
Not Qualified |
Output Type |
OPEN-COLLECTOR |
Temperature Grade |
MILITARY |
Number of Channels |
2 |
Max Supply Voltage |
36V |
Min Supply Voltage |
5V |
Power Dissipation-Max |
500mW |
Nominal Supply Current |
11mA |
Max Supply Current |
-4.2mA |
Current - Output |
25mA |
Response Time |
25 ns |
Amplifier Type |
COMPARATOR |
Common Mode Rejection Ratio |
80 dB |
Current - Input Bias |
475nA |
Input Offset Voltage (Vos) |
3.8mV |
Neg Supply Voltage-Nom (Vsup) |
-15V |
Average Bias Current-Max (IIB) |
0.5μA |
Max Dual Supply Voltage |
18V |
Min Dual Supply Voltage |
2.5V |
Total Dose |
100k Rad(Si) V |
Height |
5.08mm |
Length |
19.56mm |
Width |
6.67mm |
Thickness |
4.57mm |
Radiation Hardening |
Yes |
RoHS Status |
RoHS Compliant |
Lead Free |
Contains Lead |
LM119JRLQMLV Overview
Packaging for the buffer amplifier is in the form of a CDIP case. A COMPARATOR-type buffer amplifier is shown here. It is estimated that there will be at least 14 terminations this year. A total of 14 pins are located on this board. I would like you to keep in mind that this buffer amplifier needs to be run at a voltage of 15V. There are two types of Comparator op amps in this case, and this device falls into one of them. A total of 14 pins are present on the instrumentation amplifier. Regarding input offset voltage, buffer amplifier rates 3.8mV voltage. The op amp ic has 2 channels on it. This op amp ic outputs OPEN-COLLECTOR signals, which is one of the many benefits it has. For this linear amplifier to work, the temperature should not be below -55°C. You should only use op amp buffer at temperatures that are no higher than 125°C. A TUBE-shaped amplifier is used to pack the buffer amps. With regard tp supply voltage, op amp is used under 36V. In order to ensure that the instrumentation amplifier's supply voltage remains above 5V, it is recommended to keep it higher. Conduct linear amplifier under the dual suuply voltage of 18V.
LM119JRLQMLV Features
14 Pins
supply voltage of 15V
Output Type: OPEN-COLLECTOR
LM119JRLQMLV Applications
There are a lot of Texas Instruments LM119JRLQMLV Instrumentational OP Amps applications.
- Proportional counter tubes
- RF cable systems
- Weighing systems
- High/low-pass filter circuit
- Commercial audio systems
- Scintillation detectors
- Inverse/same-phase proportional circuit
- Portable electronic products powered by batteries
- Video conversion and routing
- Blood pressure sensors