Parameters |
Lifecycle Status |
PRODUCTION (Last Updated: 1 week ago) |
Package / Case |
MSOP |
Number of Pins |
8 |
Max Operating Temperature |
70°C |
Min Operating Temperature |
0°C |
Number of Elements |
2 |
Number of Channels |
2 |
Number of Circuits |
2 |
Max Supply Voltage |
12.6V |
Min Supply Voltage |
2.3V |
Operating Supply Current |
15mA |
Slew Rate |
300 V/μs |
Common Mode Rejection Ratio |
66 dB |
Current - Input Bias |
12.5μA |
Output Current per Channel |
85mA |
Input Offset Voltage (Vos) |
2.5mV |
Bandwidth |
320MHz |
Gain Bandwidth Product |
160MHz |
Voltage Gain |
98.06dB |
Power Supply Rejection Ratio (PSRR) |
71dB |
Max Dual Supply Voltage |
6.3V |
-3db Bandwidth |
320MHz |
Min Dual Supply Voltage |
1.25V |
Nominal Gain Bandwidth Product |
160MHz |
Number of Amplifiers |
2 |
REACH SVHC |
No SVHC |
RoHS Status |
RoHS Compliant |
Lead Free |
Lead Free |
LT1810CMS8#PBF Overview
There is a MSOP case in which the instrumentation amplifier is packaged. A total of 8 pins are present on the instrumentation amplifier. With regards to the offset voltage of the input, buffer amplifier is rated at 2.5mV. An 15mA volt supply current is needed for this linear amplifier to operate. There should be no change in the voltage gain at 98.06dB. On this buffer amplifier, there are 2 circuits. The op amp ic has 2 channels on it. The temperature should not be lower than 0°C for operational amplifier ics to operate. It should only be used at temperatures up above 70°C. Depending on the chip's operating supply voltage, op amp ic has a rated voltage of 2. Under 12.6V is the minimum supply voltage for this electric component. In order to ensure that the instrumentation amplifier's supply voltage remains above 2.3V, it is recommended to keep it higher. The dual supply voltage of 6.3V should be used for the conduct of this electronic component. The linear amplifier has 2 amplifiers.
LT1810CMS8#PBF Features
98.06dB voltage gain
LT1810CMS8#PBF Applications
There are a lot of Analog Devices, Inc. LT1810CMS8#PBF Instrumentational OP Amps applications.
- High/low-pass filter circuit
- single/dual op amp sum and difference circuits
- Laptop
- Ultrasound transducers
- Communication device
- ECG equipment
- Addition operation circuits
- Band-stop filter
- Computer workstations
- Polarized electrodes