Parameters |
Factory Lead Time |
1 Week |
Mounting Type |
Surface Mount |
Package / Case |
TO-236-3, SC-59, SOT-23-3 |
Surface Mount |
YES |
Operating Temperature |
-40°C~125°C TA |
Packaging |
Strip |
Published |
2016 |
JESD-609 Code |
e3 |
Pbfree Code |
yes |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Number of Terminations |
3 |
ECCN Code |
EAR99 |
Type |
Simple Reset/Power-On Reset |
Terminal Finish |
Matte Tin (Sn) |
Subcategory |
Power Management Circuits |
Technology |
CMOS |
Terminal Position |
DUAL |
Terminal Form |
GULL WING |
Peak Reflow Temperature (Cel) |
260 |
Number of Functions |
1 |
Supply Voltage |
3V |
Terminal Pitch |
0.95mm |
Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
Output |
Open Drain or Open Collector |
Pin Count |
3 |
JESD-30 Code |
R-PDSO-G3 |
Qualification Status |
Not Qualified |
Supply Voltage-Max (Vsup) |
5.5V |
Number of Channels |
1 |
Adjustable Threshold |
NO |
Reset |
Active Low |
Voltage - Threshold |
1.8V |
Number of Voltages Monitored |
1 |
Reset Timeout |
100ms Minimum |
Supply Current-Max (Isup) |
0.007mA |
Threshold Voltage |
+1.8V |
Length |
2.92mm |
RoHS Status |
ROHS3 Compliant |
MAX6334UR18D3+ Overview
As far as the mounting terminals of this voltage supervisor are concerned, it has 3 in total. This power ic is packaged in a way that looks like a Strip. For your reference, this IC power includes a list of 1 functions. It is possible to find on this power management a series of 1 channels. Please refer to power management for TO-236-3, SC-59, SOT-23-3 functions. As with other Simple Reset/Power-On Reset products, this IC management also offers a wide range of benefits. In order to ensure a good reflow performance, the package peak reflow temperature must be set at 260. IC management conducts in a 3V-voltage supply. Power management conducts at a voltage of 1. Power Management Circuits is a subcategory of this PMIC chip. It has a total of 3 pins that are attached to IC management. Power management recommends the Surface Mount mounting type. It is recommended to set the supervisor's temperature to this range: -40°C~125°C TA. Power management has an output of Open Drain or Open Collector during operation.
MAX6334UR18D3+ Features
Simple Reset/Power-On Reset type
MAX6334UR18D3+ Applications
There are a lot of Maxim Integrated MAX6334UR18D3+ Voltage Supervisors applications.
- Leakage current detection
- Precision measurement
- Electric heating appliances
- Power distribution systems of ICU
- Urban rail transit weak current power monitoring
- Dash board
- Cloud computing
- Multi-voltage system
- Transformer load monitoring equipment
- Power distribution systems of operating room