Parameters |
Subcategory |
Power Management Circuits |
Max Power Dissipation |
247mW |
Technology |
BICMOS |
Terminal Position |
DUAL |
Terminal Form |
GULL WING |
Peak Reflow Temperature (Cel) |
260 |
Number of Functions |
1 |
Pin Count |
5 |
Temperature Grade |
INDUSTRIAL |
Number of Channels |
1 |
Max Supply Voltage |
5.5V |
Min Supply Voltage |
1V |
Operating Supply Current |
10μA |
Adjustable Threshold |
YES |
Watchdog Timer |
No |
Reset |
Active Low |
Number of Voltages Monitored |
3 |
Reset Timeout |
150 ms |
Threshold Voltage |
4.625V |
Undervoltage Threshold |
3V |
Overvoltage Threshold |
3.15V |
Height Seated (Max) |
1.1mm |
Length |
2mm |
RoHS Status |
ROHS3 Compliant |
Factory Lead Time |
1 Week |
Mount |
Surface Mount |
Number of Pins |
5 |
Packaging |
Strip |
Published |
2006 |
JESD-609 Code |
e3 |
Pbfree Code |
yes |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Number of Terminations |
5 |
ECCN Code |
EAR99 |
Type |
Multi-Voltage Supervisor |
Terminal Finish |
Matte Tin (Sn) |
Max Operating Temperature |
85°C |
Min Operating Temperature |
-40°C |
MAX6740XKLTD3+T Overview
It is mounted through 5 terminals on the power management. Packaging is in the form of a Strip. As a reference, this IC management includes 1 functions for your convenience. On this supervisor, there is a series of 1 channels that can be found. There are a lot of similarities between this IC management and other Multi-Voltage Supervisor products. Packages are specified to have an average peak reflow temperature of 260. When a supply voltage of 3 is applied to the power ic, it conducts. The mount is provided by Surface Mount. There is a subcategory called Power Management Circuits for this power management. In total, the power management has 5 pins in it. 5 pins are on the supervisor. In order for this PMIC to work correctly, the minimum supply voltage (Vsup) should be greater than 1V. In this PMIC, the maximum supply voltage (Vsup) should not exceed 5.5V volts. There is a supply current of 10μA for the power management.
MAX6740XKLTD3+T Features
Multi-Voltage Supervisor type
Minimum supply voltage of 1V
10μA operating supply current
MAX6740XKLTD3+T Applications
There are a lot of Maxim Integrated MAX6740XKLTD3+T Voltage Supervisors applications.
- Detection of phase imbalance
- Data storage applications
- Military communications
- Low voltage/high power - AI, GPU
- Medical-specific isolation transformer
- Microprocessor system
- DC stabilized power supply module
- Military electronics
- Precision measurement
- Power distribution systems of CCU