Parameters |
Factory Lead Time |
1 Week |
Mounting Type |
Surface Mount |
Package / Case |
5-TSSOP, SC-70-5, SOT-353 |
Surface Mount |
YES |
Operating Temperature |
-40°C~85°C TA |
Packaging |
Tape & Reel (TR) |
Published |
2006 |
JESD-609 Code |
e3 |
Pbfree Code |
yes |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Number of Terminations |
5 |
ECCN Code |
EAR99 |
Type |
Multi-Voltage Supervisor |
Terminal Finish |
Matte Tin (Sn) |
Subcategory |
Power Management Circuits |
Technology |
BICMOS |
Terminal Position |
DUAL |
Terminal Form |
GULL WING |
Peak Reflow Temperature (Cel) |
260 |
Number of Functions |
1 |
Terminal Pitch |
0.65mm |
Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
Base Part Number |
MAX6741 |
Output |
Open Drain or Open Collector |
Pin Count |
5 |
JESD-30 Code |
R-PDSO-G5 |
Qualification Status |
Not Qualified |
Supply Voltage-Max (Vsup) |
5.5V |
Power Supplies |
1.5/5V |
Number of Channels |
1 |
Adjustable Threshold |
YES |
Reset |
Active Low |
Voltage - Threshold |
1.575V 2.625V |
Number of Voltages Monitored |
2 |
Reset Timeout |
150ms Minimum |
Threshold Voltage |
+2.625V |
Height Seated (Max) |
1.1mm |
RoHS Status |
ROHS3 Compliant |
MAX6741XKRVD3+T Overview
It is mounted through 5 terminals on the power management. This power ic is packaged in a way that looks like a Tape & Reel (TR). For your reference, this IC power includes a list of 1 functions. There are 1 channels available on this supervisor, and each channel has a different function. IC management is packaged as a 5-TSSOP, SC-70-5, SOT-353 package. There are many benefits that this IC power shares with other Multi-Voltage Supervisor products as well. As specified in the package specification, the peak reflow temperature of the package is set at 260. IC management is possible to find a succession of 2 voltages that have been checked. As a subcategory, this PMIC chip can be categorized as Power Management Circuits. Power management has a total of 5 pins. In this case, Surface Mount is the recommended mounting type. We recommend setting the supervisors to -40°C~85°C TA degrees. When this power management system is in operation, it produces an output voltage of Open Drain or Open Collector. It is always advisable to use MAX6741, the base supervisor number, when searching for similar PMICs from the manufacturer. To be able to work, this power management requires 1.5/5V volts of power.
MAX6741XKRVD3+T Features
Multi-Voltage Supervisor type
MAX6741XKRVD3+T Applications
There are a lot of Maxim Integrated MAX6741XKRVD3+T Voltage Supervisors applications.
- Stable power system
- Household appliances
- Precision measurement
- Solar power charger
- Medical-specific isolation transformer
- DC stabilized power supply module
- Functional modules
- Smart meter
- Detection of phase loss
- Magnetic resonance imaging