Parameters |
Factory Lead Time |
1 Week |
Mounting Type |
Through Hole |
Package / Case |
16-DIP (0.300, 7.62mm) |
Surface Mount |
NO |
Operating Temperature |
0°C~70°C TA |
Packaging |
Tube |
Published |
1997 |
JESD-609 Code |
e3 |
Pbfree Code |
yes |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Number of Terminations |
16 |
ECCN Code |
EAR99 |
Type |
Multi-Voltage Supervisor |
Terminal Finish |
MATTE TIN |
Additional Feature |
4 PRECISION VOLTAGE COMPARATOR FOR UNDERVOLTAGE/OVERVOLTAGE MONITORING |
Technology |
CMOS |
Terminal Position |
DUAL |
Peak Reflow Temperature (Cel) |
260 |
Number of Functions |
1 |
Supply Voltage |
5V |
Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
Base Part Number |
MAX8213 |
Output |
Open Drain or Open Collector |
Pin Count |
16 |
JESD-30 Code |
R-PDIP-T16 |
Qualification Status |
Not Qualified |
Supply Voltage-Max (Vsup) |
11V |
Supply Voltage-Min (Vsup) |
2.7V |
Number of Channels |
5 |
Adjustable Threshold |
NO |
Reset |
Active Low |
Voltage - Threshold |
5Adjustable Threshold Voltages |
Number of Voltages Monitored |
5 |
Reset Timeout |
<1ms Minimum |
Supply Current-Max (Isup) |
0.033mA |
Width |
7.62mm |
RoHS Status |
ROHS3 Compliant |
Lead Free |
Lead Free |
MAX8213BCPE+ Overview
It is mounted through 16 terminals on the power management. It is packaged with Tube. Please find attached 1 functions for your reference in this IC power. There are a total of 5 channels on this supervisor, and they are arranged in a series. There are 16-DIP (0.300, 7.62mm) functions included in this PMIC so that you can refer to them. Several of the benefits of this PMIC are also shared by other Multi-Voltage Supervisor products. Packages are specified to have an average peak reflow temperature of 260. IC management conducts at a voltage of 5V. IC management is possible to find a succession of 5 voltages that have been checked. A total of 16 pins are located on this power management. Power management recommends the Through Hole mounting type. Temperature setting for the supervisors should be 0°C~70°C TA. During operation, this power management system outputs Open Drain or Open Collector. As well as this, there are other features to mention such as [0], for example. It is always advisable to use MAX8213, the base supervisor number, when searching for similar PMICs from the manufacturer.
MAX8213BCPE+ Features
Multi-Voltage Supervisor type
MAX8213BCPE+ Applications
There are a lot of Maxim Integrated MAX8213BCPE+ Voltage Supervisors applications.
- Data storage applications
- Important electronics for automotive safety
- Smart meter
- Medical-specific insulation monitor
- Detection of phase loss
- Linux and server computing
- Dash board
- Electric heating appliances
- Refrigeration
- Electronics installed in the vehicle