Parameters |
Factory Lead Time |
1 Week |
Mount |
Surface Mount |
Mounting Type |
Surface Mount |
Package / Case |
8-SOIC (0.154, 3.90mm Width) |
Number of Pins |
8 |
Operating Temperature |
-40°C~125°C |
Packaging |
Tape & Reel (TR) |
Published |
2013 |
Series |
Triaxis® |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
3 (168 Hours) |
Number of Terminations |
8 |
Voltage - Supply |
5V |
Terminal Position |
DUAL |
Terminal Form |
GULL WING |
Peak Reflow Temperature (Cel) |
NOT SPECIFIED |
Number of Functions |
1 |
Supply Voltage |
5V |
Frequency |
DC~100kHz |
Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
Output |
Ratiometric, Voltage |
Pin Count |
8 |
Operating Supply Voltage |
5.5V |
Supply Voltage-Min (Vsup) |
4.5V |
Number of Channels |
1 |
Analog IC - Other Type |
ANALOG CIRCUIT |
Operating Supply Current |
11mA |
Polarization |
Bidirectional |
Nominal Supply Current |
11mA |
Output Current |
1mA |
Max Supply Current |
16mA |
Accuracy |
±0.2% |
Response Time |
8μs |
Sensor Type |
Hall Effect, Open Loop |
Linearity |
±0.05% |
Sensitivity |
280mV/mT |
For Measuring |
AC/DC |
Current - Sensing |
10mT |
Width |
3.9mm |
RoHS Status |
RoHS Compliant |
Lead Free |
Lead Free |
MLX91205KDC-AAL-003-RE Overview
Current sensors are housed in 8-SOIC (0.154, 3.90mm Width) packages to ensure their safety. In order to protect these current sensors, the Tape & Reel (TR) is used to protect them. In order for current sensors to be effective, their current supply should not exceed 16mA. There is a 8 termination on the current sensors. As far as the current sensor is concerned, it has 8 pins. When operating, the sensors could supply 5.5V. While working, these current sensors can supply a voltage of 5V. Current sensors should have a 4.5V minimum voltage. Pins 8 are present on this electronic component. It is expected that a current sensor should supply a current of 11mA nominally. Current sensors should output a value of 1mA. In order for these electronic components to perform correctly, the current supplied by them should be 11mA.
MLX91205KDC-AAL-003-RE Features
Moisture Sensitivity Level: 3 (168 Hours)
Operating Temperature: -40°C~125°C
1 Channels
Mounting Type: Surface Mount
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 5V
Frequency: DC~100kHz
Sensing Current: 10mT
8-SOIC (0.154, 3.90mm Width) Package
MLX91205KDC-AAL-003-RE Applications
There are a lot of Melexis Technologies NV MLX91205KDC-AAL-003-RE Current Sensors applications.
- Uninterruptible Power Supplies(UPS)
- DC and AC power monitoring
- Switched Mode Power Supplies(SMPS)
- Motor and load control
- Monitor Motor Operation
- Mobile applications
- Electrical drives
- Closed-L oop DC- and AC-Current Sensor Modules
- Uninterruptable Power Supllies (UPS)
- Frequency, Voltage, and Solar Inverters