Parameters |
Factory Lead Time |
1 Week |
Mount |
Surface Mount |
Mounting Type |
Surface Mount |
Package / Case |
8-SOIC (0.154, 3.90mm Width) |
Operating Temperature |
-40°C~125°C |
Packaging |
Tube |
Published |
2011 |
Series |
Triaxis® |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
3 (168 Hours) |
Number of Terminations |
8 |
Voltage - Supply |
5V |
Terminal Position |
DUAL |
Terminal Form |
GULL WING |
Peak Reflow Temperature (Cel) |
NOT SPECIFIED |
Number of Functions |
1 |
Supply Voltage |
5V |
Frequency |
DC~100kHz |
Time@Peak Reflow Temperature-Max (s) |
NOT SPECIFIED |
Output |
Ratiometric, Voltage |
Pin Count |
8 |
JESD-30 Code |
R-PDSO-G8 |
Operating Supply Voltage |
5.5V |
Supply Voltage-Min (Vsup) |
4.5V |
Number of Channels |
1 |
Analog IC - Other Type |
ANALOG CIRCUIT |
Polarization |
Bidirectional |
Nominal Supply Current |
11mA |
Output Current |
1mA |
Max Supply Current |
16mA |
Accuracy |
±0.2% |
Response Time |
8μs |
Sensor Type |
Hall Effect, Open Loop |
Linearity |
±0.05% |
Sensitivity |
280mV/mT |
For Measuring |
AC/DC |
Current - Sensing |
10mT |
Length |
4.89mm |
Width |
3.9mm |
RoHS Status |
RoHS Compliant |
Lead Free |
Lead Free |
MLX91205KDC-AAL-003-TU Overview
For safety reasons, the current sensors are enclosed in 8-SOIC (0.154, 3.90mm Width) packages. For protection, these sensors are packaged in the Tube. It is recommended that current sensors provide a current that is not greater than 16mA. There is a 8 termination on the current sensors. As long as the current sensors are functioning, they may supply 5.5V voltage. These current sensors can supply a voltage of 5V while working. Current sensors should have a 4.5V minimum voltage. A 8 pin electronic part is used in this product. By definition, current sensors should provide a 11mA current. Current sensors should produce a 1mA output.
MLX91205KDC-AAL-003-TU Features
Moisture Sensitivity Level: 3 (168 Hours)
Operating Temperature: -40°C~125°C
1 Channels
Mounting Type: Surface Mount
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 5V
Frequency: DC~100kHz
Sensing Current: 10mT
8-SOIC (0.154, 3.90mm Width) Package
MLX91205KDC-AAL-003-TU Applications
There are a lot of Melexis Technologies NV MLX91205KDC-AAL-003-TU Current Sensors applications.
- Industrial Monitoring and Control Systems
- Static converters for DC motor drives
- AC variable speed drives
- Power factor correction
- Electrical drives
- Continuity
- Overcurrent protection
- General purpose inverters
- Monitor Motor Operation
- Static converters for for DC motor drives