Parameters |
Factory Lead Time |
1 Week |
Mount |
Surface Mount |
Mounting Type |
Surface Mount |
Package / Case |
8-SOIC (0.154, 3.90mm Width) |
Operating Temperature |
-40°C~125°C |
Packaging |
Tape & Reel (TR) |
Published |
2015 |
Series |
Triaxis® |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
3 (168 Hours) |
Number of Terminations |
8 |
Resistance |
1Ohm |
Subcategory |
Other Sensors/Transducers |
Voltage - Supply |
4.5V~5.5V |
Frequency |
DC~200kHz |
Output |
Ratiometric, Voltage (Selectable) |
Body Length or Diameter |
4.89mm |
Body Breadth |
3.9 mm |
Power Supplies |
5V |
Number of Channels |
1 |
Termination Type |
SOLDER |
Polarization |
Bidirectional |
Max Supply Current |
14mA |
Accuracy |
±0.1% |
Response Time |
3μs |
Sensor Type |
Hall Effect, Open Loop |
Linearity |
±0.75% |
Sensors/Transducers Type |
MAGNETIC FIELD SENSOR,HALL EFFECT |
Sensitivity |
100mV/mT |
For Measuring |
AC/DC |
Hysteresis |
0.025 mT |
Magnetic Field Range-Min |
-25 mT |
Magnetic Field Range-Max |
25 mT |
RoHS Status |
RoHS Compliant |
Lead Free |
Lead Free |
MLX91208LDC-CAH-000-RE Overview
Safety measures are taken to protect the current sensors by putting them in 8-SOIC (0.154, 3.90mm Width) packages. It is designed to protect the current sensors from damage by packaging them in the Tape & Reel (TR). A current sensor should not provide a current greater than 14mA. There is a termination of 8 on the current sensors.
MLX91208LDC-CAH-000-RE Features
Moisture Sensitivity Level: 3 (168 Hours)
Operating Temperature: -40°C~125°C
1 Channels
Mounting Type: Surface Mount
Sensor Type: Hall Effect, Open Loop
Supply Voltage: 4.5V~5.5V
Frequency: DC~200kHz
8-SOIC (0.154, 3.90mm Width) Package
MLX91208LDC-CAH-000-RE Applications
There are a lot of Melexis Technologies NV MLX91208LDC-CAH-000-RE Current Sensors applications.
- Battery supplied applications
- Static converters for DC motor drives
- Static converters for for DC motor drives
- Battery chargers and systems
- Uninterruptible Power Supplies(UPS)
- Switched Mode Power Supplies(SMPS)
- AC variable speed drives
- Inverter and H-bridge current measurements
- Monitor Motor Operation
- Closed-L oop DC- and AC-Current Sensor Modules