Parameters |
Part Status |
Obsolete |
Moisture Sensitivity Level (MSL) |
3 (168 Hours) |
Number of Terminations |
40 |
Terminal Position |
QUAD |
Peak Reflow Temperature (Cel) |
260 |
Supply Voltage |
3.3V |
Terminal Pitch |
0.5mm |
Time@Peak Reflow Temperature-Max (s) |
40 |
Base Part Number |
SI3209 |
JESD-30 Code |
S-XQCC-N40 |
Function |
Subscriber Line Interface Concept (SLIC), CODEC |
Operating Temperature (Max) |
70°C |
Operating Supply Voltage |
3.3V |
Temperature Grade |
COMMERCIAL |
Interface |
PCM |
Number of Circuits |
2 |
Min Supply Voltage |
3.13V |
Height Seated (Max) |
1mm |
Length |
6mm |
Width |
6mm |
Radiation Hardening |
No |
RoHS Status |
RoHS Compliant |
Mount |
Surface Mount |
Mounting Type |
Surface Mount |
Package / Case |
40-VFQFN Exposed Pad |
Packaging |
Tape & Reel (TR) |
Published |
2014 |
Series |
ProSLIC® |
SI3209-B-FMR Overview
40-VFQFN Exposed Pad package is used to save board space.Telecommunications equipment is packed according to Tape & Reel (TR)'s method.Telecommunications equipment is mounted using Surface Mount.A 2 circuit is the heart of this telecom IC .Surface Mount is the way telecom switching is mounted.As part of its configuration, it includes 40 terminations.It operates with a voltage of 3.3V.By using telecom switching's base part number of SI3209, it is possible to find more related parts.The supply voltage of 3.3V enables designers to have a great deal of flexibility.A number of similar functions of the telecommunication product can be provided by it as with those of electronic parts under the ProSLIC? series.3.13V is the minimum voltage that should be supplied.70°C is the maximum operating temperature supported by telecommunication tools.
SI3209-B-FMR Features
Available in the 40-VFQFN Exposed Pad package
Operating supply voltage of 3.3V
SI3209-B-FMR Applications
There are a lot of Silicon Labs SI3209-B-FMR Telecom applications.
- Voice over IP/DSL
- Wireless base stations
- Set-Top Box
- Central office (CO)
- DSLAMs
- PCM channel bank
- Wireless local loop (WLL)
- T2 Rates PCM Line Interface
- Channel Banks
- Digital Access Cross-connect System (DACs)