Parameters |
Factory Lead Time |
1 Week |
Package / Case |
8-DIP (0.524, 13.30mm), Dual Ports, Same Side |
Surface Mount |
NO |
Number of Pins |
8 |
Operating Temperature |
-40°C~85°C |
Published |
2011 |
Series |
TruStability® SSC |
Feature |
Amplified Output, Temperature Compensated |
Pbfree Code |
yes |
Part Status |
Active |
Moisture Sensitivity Level (MSL) |
1 (Unlimited) |
Termination |
Through Hole |
Applications |
Board Mount |
Voltage - Rated DC |
5V |
Voltage - Supply |
4.75V~5.25V |
Reach Compliance Code |
unknown |
Output |
0.5 V ~ 4.5 V |
Termination Style |
PC Pin |
Body Length or Diameter |
13.35mm |
Body Breadth |
9.91 mm |
Output Voltage |
4.5V |
Output Type |
Analog Voltage |
Operating Supply Voltage |
5V |
Nominal Supply Current |
2mA |
Max Supply Current |
3mA |
Accuracy |
±0.25% |
Response Time |
1 ms |
Operating Pressure |
±0.87PSI (±6kPa) |
Pressure Type |
Differential |
Port Style |
Barbed |
Port Size |
Male - 0.08 1.93mm Tube Dual |
Maximum Pressure |
±12.33PSI (±85kPa) |
Sensors/Transducers Type |
PRESSURE SENSOR,PEIZORESISTIVE |
Housing |
CERAMIC |
RoHS Status |
RoHS Compliant |
SSCDRRN060MDAA5 Overview
This transducer is included in the package 8-DIP (0.524, 13.30mm), Dual Ports, Same Side. The temperature of the transducers should be set to -40°C~85°C to ensure reliable performance. The transducers are capable of operating well at 4.75V~5.25V supply voltage. There is a requirement that 8 pins be connected for the transducers to function properly. Normal operation of the transducers is possible with a nominal supply current of 2mA. In order for the transducers to work, the voltage discharged by them should be 4.5V. It is recommended that the DC voltage be set to 5V so that the transducers can continuously operate at their rated ambient temperature. The current of the transducers should not exceed 3mA, otherwise it will be dangerous.
SSCDRRN060MDAA5 Features
Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: 8-DIP (0.524, 13.30mm), Dual Ports, Same Side
Operating Temperature: -40°C~85°C
8 Pins
TruStability? SSC series
Operating Pressure: ±0.87PSI (±6kPa)
Operating Supply Voltage: 5V
SSCDRRN060MDAA5 Applications
There are a lot of Honeywell Sensing and Productivity Solutions SSCDRRN060MDAA5 Transducers applications.
- Navigation systems
- Mobile Phones
- Medical instrumentation
- Portable health care devices
- Weather forecast
- Altimeters
- White goods
- Indoor navigation & localization (floor detection, elevator detection)
- Kidney dialysis machines
- Indoor/Outdoor Navigation (dead-reckoning, floor/elevator/step detection)