Parameters |
Mount |
Through Hole |
Package / Case |
PDIP |
Number of Pins |
8 |
JESD-609 Code |
e4 |
Pbfree Code |
no |
Number of Terminations |
8 |
ECCN Code |
EAR99 |
Terminal Finish |
Nickel/Palladium/Gold (Ni/Pd/Au) |
Max Operating Temperature |
70°C |
Min Operating Temperature |
0°C |
Subcategory |
Operational Amplifier |
Technology |
BIPOLAR |
Terminal Position |
DUAL |
Number of Functions |
1 |
Supply Voltage |
15V |
Terminal Pitch |
2.54mm |
Pin Count |
8 |
Operating Supply Voltage |
18V |
Temperature Grade |
COMMERCIAL |
Number of Circuits |
1 |
Max Supply Voltage |
36V |
Min Supply Voltage |
7V |
Operating Supply Current |
1.4mA |
Nominal Supply Current |
2.8mA |
Slew Rate |
13 V/μs |
Architecture |
VOLTAGE-FEEDBACK |
Amplifier Type |
OPERATIONAL AMPLIFIER |
Common Mode Rejection Ratio |
70 dB |
Current - Input Bias |
30pA |
Input Offset Voltage (Vos) |
15mV |
Bandwidth |
3MHz |
Gain Bandwidth Product |
3MHz |
Neg Supply Voltage-Nom (Vsup) |
-15V |
Unity Gain BW-Nom |
3000 kHz |
Voltage Gain |
106.02dB |
Low-Offset |
NO |
Frequency Compensation |
NO |
Max Dual Supply Voltage |
18V |
Low-Bias |
YES |
Min Dual Supply Voltage |
3.5V |
Bias Current-Max (IIB) @25C |
0.0004μA |
Length |
9.59mm |
Radiation Hardening |
No |
REACH SVHC |
No SVHC |
RoHS Status |
RoHS Compliant |
Lead Free |
Contains Lead |
TL080CP Overview
There is a PDIP case in which the instrumentation amplifier is packaged. An op amp of this type is a OPERATIONAL AMPLIFIER-type. The number of terminations is approaching the 8 mark. It consists of a total of 8 pins in total. Please take in mind that op amp should be run at 15V. To be specific, this instrumentation amplifier is a type of Operational Amplifier. 8 pins are available on the instrumentation amplifier. Op amp ic rates 15mV for input offset voltage. The buffer amplifier is capable of operating from a supply current of 1.4mA . 106.02dB should remain the voltage gain. The buffer amp consists of 1 circuits in total. In order for this buffer op amp to function, it should have a temperature of at least 0°C degrees Celsius. You should only use instrumentation amplifier at temperatures that are no higher than 70°C. The operating supply voltage of instrumentation amplifier is rated 18V voltage. I would like to point out that this electrical component is capable of working from a voltage below 36V as far as the power supply is concerned. It is recommended that you keep the instrumentation amplifier's supply voltage higher than 7V when using it. There should be a dual supply voltage of 18V for you to conduct this electrical part.
TL080CP Features
8 Pins
supply voltage of 15V
106.02dB voltage gain
TL080CP Applications
There are a lot of Texas Instruments TL080CP Instrumentational OP Amps applications.
- Digital cameras
- Voltage regulation circuit
- Medical instruments
- High gain DC amplifier
- Power control
- pH (acidity)
- Ultrasound transducers
- Polarized electrodes
- Strain gauges
- Broadcasting